• Home
  • Browse
    • Current Issue
    • By Issue
    • By Author
    • By Subject
    • Author Index
    • Keyword Index
  • Journal Info
    • About Journal
    • Aims and Scope
    • Editorial Board
    • Publication Ethics
    • Peer Review Process
  • Guide for Authors
  • Submit Manuscript
  • Reviewers
  • Contact Us
 
  • Login
  • Register
Home Articles List Article Information
  • Save Records
  • |
  • Printable Version
  • |
  • Recommend
  • |
  • How to cite Export to
    RIS EndNote BibTeX APA MLA Harvard Vancouver
  • |
  • Share Share
    CiteULike Mendeley Facebook Google LinkedIn Twitter
Journal of Al-Azhar University Engineering Sector
arrow Articles in Press
arrow Current Issue
Journal Archive
Volume Volume 18 (2023)
Volume Volume 17 (2022)
Issue Issue 65
Issue Issue 64
Issue Issue 63
Issue Issue 62
Volume Volume 16 (2021)
Volume Volume 15 (2020)
Volume Volume 14 (2019)
Volume Volume 13 (2018)
Volume Volume 12 (2017)
Volume Volume 11 (2016)
El Degwy, A., Aboulmagd, A. (2022). INVESTIGATIONS OF THERMAL COMFORT AND AIR FLOW DISTRIBUTION IN NATURALLY VENTILATED LIVING ROOM WITH A CEILING FAN. Journal of Al-Azhar University Engineering Sector, 17(65), 1261-1275. doi: 10.21608/auej.2022.265714
Ahmed El Degwy; Ahmed Aboulmagd. "INVESTIGATIONS OF THERMAL COMFORT AND AIR FLOW DISTRIBUTION IN NATURALLY VENTILATED LIVING ROOM WITH A CEILING FAN". Journal of Al-Azhar University Engineering Sector, 17, 65, 2022, 1261-1275. doi: 10.21608/auej.2022.265714
El Degwy, A., Aboulmagd, A. (2022). 'INVESTIGATIONS OF THERMAL COMFORT AND AIR FLOW DISTRIBUTION IN NATURALLY VENTILATED LIVING ROOM WITH A CEILING FAN', Journal of Al-Azhar University Engineering Sector, 17(65), pp. 1261-1275. doi: 10.21608/auej.2022.265714
El Degwy, A., Aboulmagd, A. INVESTIGATIONS OF THERMAL COMFORT AND AIR FLOW DISTRIBUTION IN NATURALLY VENTILATED LIVING ROOM WITH A CEILING FAN. Journal of Al-Azhar University Engineering Sector, 2022; 17(65): 1261-1275. doi: 10.21608/auej.2022.265714

INVESTIGATIONS OF THERMAL COMFORT AND AIR FLOW DISTRIBUTION IN NATURALLY VENTILATED LIVING ROOM WITH A CEILING FAN

Article 9, Volume 17, Issue 65, October 2022, Page 1261-1275  XML PDF (865.32 K)
Document Type: Original Article
DOI: 10.21608/auej.2022.265714
Authors
Ahmed El Degwyorcid ; Ahmed Aboulmagdorcid
Mechanical Power Engineering Department, Faculty of Engineering, Cairo University, Giza 12613, Egypt
Abstract
In this paper, numerical analysis is used to investigate thermal comfort and airflow patterns in ventilated living rooms, including window openings and utilizing a ceiling fan. The air distribution in the living room was accurately predicted in this study using the CFD program. A five-bladed commercial ceiling fan is used to ventilate the room. The major goal of this study is to change the fan speed, fan height, and fan direction of rotation for the purpose of providing the thermal comfort conditions for individuals in the living room. Temperatures, velocities, the PPD index (Predicted Percentage Dissatisfied), and the PMV index (Predicted Mean Vote) distribution have all been taken into consideration while analyzing each case. The results showed that the best thermal comfort values are associated with fan placement in the center of the room at a height of 2.75 m from the floor at a rotational speed of 110 rpm. The overall level of thermal comfort is not significantly different whether downward-drive or upward-drive fans are used, but there is a substantial variation in the local level of thermal comfort in an occupied zone.

في هذا البحث ، يتم استخدام التحليل العددي للتحقق من الراحة الحرارية وأنماط تدفق الهواء في غرف المعيشة ذات التهوية بما في ذلك فتحات النوافذ مع استخدام مروحة السقف. تم التنبؤ بدقة بتوزيع الهواء في غرفة المعيشة في هذه الدراسة باستخدام برنامج تحليل عدادى  (بإستخدام ديناميكا الموائع الحسابيه). تستخدم مروحة سقف تجارية بخمس شفرات لتهوية الغرفة. الهدف الرئيسي من هذه الدراسة هو تغيير سرعة المروحة وارتفاعها واتجاه دوران المروحة لغرض توفير ظروف الراحة الحرارية للأفراد في غرفة المعيشة. تم أخذ توزيع درجات الحرارة والسرعات ومؤشر (النسبة المئوية المتوقعة غير الراضية) ومؤشر (متوسط التصويت المتوقع) في الاعتبار أثناء تحليل كل حالة. أظهرت النتائج أن أفضل قيم الراحة الحرارية مرتبطة بوضع المروحة في وسط الغرفة على ارتفاع 2.75 متر من الأرضية، بسرعة دوران 110 دورة في الدقيقة. لا يختلف المستوى العام للراحة الحرارية اختلافًا كبيرًا سواء تم استخدام مراوح الدفع إلى الأسفل أو الدفع لأعلى ، ولكن هناك تباينًا كبيرًا في المستوى المحلي للراحة الحرارية في منطقة مشغولة.
Keywords
Fan; CFD; Thermal Comfort; PPD; PMV
Main Subjects
Mechanical engineering
Statistics
Article View: 121
PDF Download: 74
Home | Glossary | News | Aims and Scope | Sitemap
Top Top

Journal Management System. Designed by NotionWave.